Support -
Product Reference - Alcavis
50
Preparation of Central Venous Catheter for Initiation
and Discontinuation of Hemodialysis Treatment
Purpose:
To prevent contamination and infection of the dialysis catheter
access during initiation and discontinuation of the hemodialysis
treatment.
Supplies:
Alcavis 50 solution, 2 packages of sterile 4x4 gauze pads,
chux sheet, sterile underpad, non sterile gloves, staff face
shield, patient mask.
Procedure:
- Staff should wash their hands and don
a face shield. Patient should don a face mask.
- A sterile underpad should be placed
under the catheter.
- On a chux sheet, carefully open both
packages of 4x4 gauze pads keeping pads on sterile wrappers.
- Saturate both sets of 4x4 gauze pads
with ample amounts of Alcavis 50 solution (10 to
15 cc's for each gauze pad).
- Put on clean non sterile gloves.
- Carefully place the catheter venous
port in an Alcavis 50 saturated 4x4 gauze pad and
scrub the catheter end and port for 1 minute.
- Carefully place the catheter arterial
port in an Alcavis 50 saturated 4x4 gauze pad and
scrub the catheter end and port for 1 minute. Make sure
to rub in an agitating motion when cleaning ports.
- Carefully wrap the arterial port in
an Alcavis 50 saturated gauze pad.
- Carefully wrap the venous port in an
Alcavis 50 saturated gauze pad. Leave each port wrapped
for at least 2 minutes.
- Carefully unwrap the catheter ports
for initiation of dialysis treatment as per clinic protocol.
- Repeat this process for the discontinuation
of the dialysis treatment as per clinic protocol.
up
Amu-Safe Procedure
Purpose:
To disinfect dialysis disposables.
Supplies:
Alcavis 50, PPE, non-sterile gloves.
Procedure:
- After completion of C.A.P.D., exchange procedure.
Leave Alcavis 50 in upright position, twist luer
connector of the Y-set onto Alcavis 50.
- Turn Alcavis 50 over and elevate bottle
to eye level.
- Visually locate measurements on side of bottle.
- Unclamp outlet port clamp on the drain line.
- Squeeze bottle until you have infused 25ml.
- Clamp outlet port clamp on drain line.
- Place bottle in upright position.
- Disconnect bottle, cap bottle and store from
sunlight.
- Wait 5 minutes before disposing of solution
and tubing.
up
Transfer Set Change using
Alcavis 50
Purpose:
To change the transfer set using a sterile technique.
Supplies:
Alcavis 50, sterile gloves, 3 packages of sterile 3x3
gauze pads, 2 sterile drapes, plastic clamp without teeth
or seam, transfer set and other supplies to complete exchange,
2 masks.
Procedure:
- Have patient remove transfer set from
clothing.
- Place plastic clamp on the peritoneal
catheter.
- Staff should wash their hands and don
a face shield. Patient should don a face mask.
- Open sterile drape.
- Open all packages of sterile 3x3's.
Saturate two packages of 3x3's with Alcavis 50 (at
least 20 cc's for each gauze pad).
- Have patient pick up catheter and transfer
set.
- Nurse needs to place the sterile drape
under the catheter and transfer set, and have patient drop
transfer set onto the drape.
- Prepare transfer set to be attached
at this time.
- Put on sterile gloves.
- Pick up the first set of 3x3's saturated
with Alcavis 50, and scrub at connection between transfer
set and patient catheter, maintaining contact for one minute.
- Using the second set of Alcavis
50 saturated 3x3's, scrub the connection site for another
minute, maintaining contact time.
- Pick up dry 3x3's, and drop patient
transfer set and catheter into dry 3x3.
- Using twisting motion, disconnect patient
transfer set.
- Pick up new transfer set, maintaining
sterility, and apply new transfer set to catheter making
sure connection is tight.
- Discard used supplies and proceed with
exchange.
up
Procedure for Disinfecting Minicap Transfer Set after Contamination
Purpose:
To disinfect the end of the transfer set after a touch contamination.
Supplies:
Sterile specimen cup, bottle of Alcavis 50, mask, sterile
minicap.
Procedure:
- Wash hands.
- Using sterile procedure, open sterile
cup.
- Open minicap.
- Fill cup 1/2 -3/4 with Alcavis
50.
- Place end of the transfer set, into
Alcavis 50, and soak for 1 minute.
- Remove transfer set. Using sterile
procedure apply new minicap.
- Teach patient to observe patient for
signs and symptoms of peritonitis and to call unit if symptoms
develop.
up
Procedure for Having Patient
Disinfect Minicap Transfer After Contamination at Home
Purpose:
To disinfect the end of the transfer set after a touch contamination
at home.
Supplies to give to patient:
3 sterile specimen cups (extras to keep at home), bottle
of Alcavis 50, mask, sterile minicap.
Procedure:
- Wash hands.
- Using sterile procedure, open sterile cup.
- Open minicap.
- Fill cup 1/2 -3/4 with Alcavis 50.
- Place end of the transfer set, into Alcavis
50, and soak for 1 minute.
- Remove transfer set. Using sterile procedure
apply new minicap.
- Teach patient to observe for signs and symptoms
of peritonitis and to call unit if symptoms develop.
- Teach patient to record symptoms, on his/her
logs when they need to, and to call the unit or nurse on
call if they have any problems.
up
Adding Intraperitoneal Medication to Dianeal
Purpose:
To add prescribed medication to
dianeal in a sterile manner.
Supplies:
Appropriate dianeal solution, Alcavis 50, syringes
(number depends on volume of medication to be given), sterile
needles (22g. 1/12in.), appropriate medications, mask, labels,
tape, 2x2 gauze pads (2 packages).
Procedure:
- Don Mask.
- Check medication bottle or prefilled
syringe for correct type, dose and expiration date.
- Aseptically place Alcavis 50
soaked 2x2's on rubber port of medication vial and dianeal.
- Leave Alcavis 50 soaked 2x2's
in place for two minutes. Open syringe and aseptically attach
sterile needle to syringe. Draw up prescribed amount of
medication. Recheck amount of medication.
- Recap needle loosely on syringe and
lay on dominant side. Remove Alcavis 50 2x2's from
med port and position in non-dominant hand without contaminating.
- Retrieve syringe in dominant hand and
withdraw cap.
- Insert needle through medication port
of dianeal bag and inject medications. Aspirate dialysate
into syringe and reinstall.
- Mix medication thoroughly by inverting
bag several times.
- Label bag with medication, dosage,
time, date, and nurse's initials.
up | Back
to Products - Alcavis 50
|